VAV terminal units

layer

TA-Silenzio

Rectangular VAV terminal units for the extract air control in buildings with variable air volume systems, demanding acoustic requirements and low airflow velocities

  • Highly effective integral attenuator
  • Optimised for airflow velocities of 0.7 – 7 m/s
  • High control accuracy, even in case of unfavourable upstream conditions
  • Compact construction with rectangular connections on both ends
  • Electronic control components for different applications (Easy, Compact, Universal, and LABCONTROL)
  • Closed blade air leakage to EN 1751, up to class 4
  • Casing leakage to EN 1751, class C



Optional equipment and accessories

  • Acoustic cladding for the reduction of case-radiated noise
  • Secondary silencer Type TS for the reduction of air-regenerated noise

 


 


 

read more

layer

TVA

VAV terminal units for extract air control in buildings with variable air volume systems and demanding acoustic requirements

  • Highly effective integral attenuator
  • Box style construction for the reduction of the airflow velocity
  • Electronic control components for different applications (Easy, Compact, Universal, and LABCONTROL)
  • Closed blade air leakage to EN 1751, up to class 4
  • Casing air leakage to EN 1751, up to class C

 

Optional equipment and accessories

  • Acoustic cladding for the reduction of case-radiated noise
  • Secondary silencer Type TS for the reduction of air-regenerated noise

 


 


 

read more

layer

TZ-Silenzio

 


Rectangular VAV terminal units for the supply air control in buildings with variable air volume systems, demanding acoustic requirements and low airflow velocities

  • Highly effective integral attenuator
  • Optimised for airflow velocities of 0.7 – approx. 7 m/s
  • High control accuracy, even in case of unfavourable upstream conditions
  • Compact construction with rectangular connections on both ends
  • Electronic control components for different applications (Easy, Compact, Universal, and LABCONTROL)
  • Closed blade air leakage to EN 1751, Class 4
  • Casing leakage to EN 1751, Class C


Optional equipment and accessories

  • Acoustic cladding for the reduction of case-radiated noise
  • Secondary silencer Type TS for the reduction of air-regenerated noise
  • Hot water heat exchanger of Type WT for reheating the airflow

 


 


 

read more

layer

TVT


 

Rectangular air terminal units for standard applications in supply air or extract air systems with variable volume flow rates, suitable for low-leakage shut-off

  • For volume flow rate ranges up to 28836 m³/h or 8010 l/s
  • Suitable for the control of volume flow rate, room pressure or duct pressure
  • Electronic control components for different applications (Easy, Compact, Universal, and LABCONTROL)
  • High control accuracy
  • Closed blade air leakage to EN 1751, class 3
  • Casing air leakage to EN 1751, up to class C

 

 

 

Optional equipment and accessories

  • Acoustic cladding for the reduction of case-radiated noise
  • Secondary silencer Type TX for the reduction of air-regenerated noise
  • Hot water heat exchanger of Type WT for reheating the airflow

 

 

 


read more

layer

TVM


 

VAV dual duct terminal units for dual duct systems with variable volume flows in buildings with demanding acoustic requirements

  • Individual temperature control for each room or zone
  • Highly effective integral attenuator
  • Electronic control components for various applications
  • Closed blade air leakage to EN 1751, up to class 4
  • Casing leakage to EN 1751, Class B

 

 

Optional equipment and accessories

  • Acoustic cladding for the reduction of case-radiated noise
  • Secondary silencer Type TS for the reduction of air-regenerated noise

 

 

 


read more

layer

TVR


  • Circular air terminal units for standard applications in supply air or extract air systems with variable volume flow rates
  • Suitable for the control of volume flow rate, room pressure or duct pressure
  • Electronic control components for different applications (Easy, Compact, Universal, and LABCONTROL)
  • High control accuracy even with upstream bend (R = 1D)
  • Closed blade air leakage to EN 1751, up to class 4
  • Casing air leakage to EN 1751, class C

 

Optional equipment and accessories

  • Acoustic cladding for the reduction of case-radiated noise
  • Secondary silencer CA (for Germany and Switzerland), CAH (for EMEA) CS or CF for the reduction of air-regenerated noise
  • Hot water heat exchanger WL and electric air heater EL for reheating the airflow

read more

layer

TVZ


VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

  • Highly effective integral attenuator
  • Box style construction for the reduction of the airflow velocity
  • Electronic control components for different applications (Easy, Compact, Universal, and LABCONTROL)
  • Closed blade air leakage to EN 1751, up to class 4
  • Casing air leakage to EN 1751, up to class C

 

Optional equipment and accessories

  • Acoustic cladding for the reduction of case-radiated noise
  • Secondary silencer Type TS for the reduction of air-regenerated noise
  • Hot water heat exchanger of Type WT for reheating the airflow

 

 

 


read more

layer

TVRK


 

Plastic circular VAV terminal units for aggressive extract air in variable air volume systems

  • Casing and damper blade made of flame-resistant polypropylene
  • Slide-out effective pressuresensor allows for easy cleaning
  • Suitable for the control of volume flow rate, room pressure or duct pressure
  • Electronic control components for different applications (Universal and LABCONTROL)
  • Suitable for airflow velocities up to 13 m/s
  • Closed blade air leakage to EN 1751, class 3
  • Casing air leakage to EN 1751, class B

 

 

 

Optional equipment and accessories

  • With flanges on both ends
  • Matching flanges for both ends
  • Plastic secondary silencer Type CAK for the reduction of air-regenerated noise

 

 

 


read more

layer

TVE

Circular air terminal units for variable air volume systems with low airflow velocities, suitable even with unfavourable upstream conditions

  • Effective pressure measurement not with a tube, but by means of the damper blade
  • Effective pressure transmission through effective pressure channel in the shaft
  • Terminals with protective cover, no junction box required
  • Any airflow direction if dynamic transducer is used
  • Suitable for airflow velocities of 0.5 – 13 m/s
  • Compact dimensions allow for use in restricted spaces
  • Plug-and-play solution in conjunction with X-AIRCONTROL room control
  • Exact measurement even with low airflow velocities
  • Any installation orientation even with static transducer
  • Closed blade air leakage to EN 1751, at least class 3
  • Casing air leakage to EN 1751, class C
  • Volume flow rate range 1:25

Optional equipment and accessories

  • Acoustic cladding for the reduction of case-radiated noise
  • Secondary silencer CA (for Germany and Switzerland), CAH (for EMEA) or CF for the reduction of air-regenerated noise
  • Hot water heat exchanger WL and electric air heater EL for reheating the airflow

read more

layer

TVJ


 

Rectangular air terminal units for standard applications in supply air or extract air systems with variable volume flow rates

  • Suitable for volume flow rate ranges up to approx. 62,000 m³/h or 17,000 l/s
  • Suitable for the control of volume flow rate, room pressure or duct pressure
  • Electronic control components for different applications (Easy, Compact, Universal, and LABCONTROL)
  • High control accuracy
  • Closed blade air leakage to EN 1751, Class 1 (B + H ≥ 600 mm) 
  • Casing air leakage to EN 1751, class B

 

 

 

Optional equipment and accessories

  • Acoustic cladding for the reduction of case-radiated noise
  • Secondary silencer Type TX for the reduction of air-regenerated noise
  • Hot water heat exchanger Type WT for reheating the airflow

 

 

 


read more

layer

TVLK

Plastic circular VAV terminal units for aggressive extract air in laboratories and production facilities

  • Casing and damper blade made of flame-resistant polypropylene
  • Compact construction, only 400 mm long
  • High control accuracy even in case of unfavourable upstream conditions
  • Combination with fast-running actuators (air management systems)
  • Volume flow rate measurement with bluff body or nozzle
  • Slide-out sensor tubes allow for easy cleaning
  • Closed blade air leakage to EN 1751, class 4
  • Casing air leakage to EN 1751, class C

 

 Optional equipment and accessories

  • With flanges on both ends
  • Plastic secondary silencer Type CAK for the reduction of air-regenerated noise

 

 

 


read more

layer

TVR-Ex

Circular VAV terminal units for variable air volume systems, approved and certified for potentially explosive atmospheres (ATEX)

  • ATEX-compliant construction and parts

  • Approved for all gases, mists and vapours in zones 1 and 2, with electronic control additionally for dusts in zones 21 and 22

  • Suitable for the control of supply or extract air as well as for differential pressure control

  • Electronic or pneumatic control components

  • Closed blade air leakage to EN 1751, up to class 4

  • Casing air leakage to EN 1751, class C

 


Optional equipment and accessories

  • Spring return actuator

  • Auxiliary switch with adjustable switching points for capturing the end positions

 

read more

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Content-Security-Policy"=>"frame-ancestors 'self' https://api.scrivito.com https://punchoutcommerce.com https://www.trox.de https://trox-extern.com https://psp40.onventis.com https://psp22.onventis.com https://trox4u.troxgroup.com", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Share page

Recommend this page

Recommend this page by sending a link by mail.

Fields marked with an (*) are required fields.

Share page

Thank you for your recommendation!

Your recommendation has been sent and should arrive shortly.

Contact

We are here for you

Please specify your message and type of request.
Tel.: +43 1 250 43-0 | Fax: +43 1 250 43 34

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +43 1 250 43-0| Fax: +43 1 250 43 34

Contact

We are here for you

Please specify your message and type of request.
Tel.: +43 1 250 43-0 | Fax: +43 1 250 43 34

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +43 1 250 43-0| Fax: +43 1 250 43 34